Page view 210
10-3
PRECAUTIONS :
Wear rubber gloves while handling
a battery.
Use only constant current battery
charger of correct charging rate, to
charge batteries.
Remove the filler caps only to fill
distilled water OR if the battery is
to be charged. Hydration may occur
when atmospheric air contacts the
plates.
Keep all the filler caps removed while
charging the battery.
Use only distilled water to top up the
level after the initial charging.
During charging, the electrolyte
temperature should not exceed 45ºC
if necessary, discontinue the
charging to cool the electrolyte.
Ensure that the battery is placed on
a non-metallic surface while
charging.
Keep fire and spark away from
battery charging area.
Never run the motorcycle without
connecting the battery as it may lead
premature failure of electrical parts.
CHARGING
INITIAL CHARGE (NEW BATTERY)
ELECTROLYTE :
Diluted sulphuric acid with distilled
water to a specific gravity of 1.240
PREPARATION :
Take required distilled water in a
Hydrometer or equivalent container.
Slowly, add sulphuric acid to it.
CAUTION :
It is important to ensure that the
sulphuric acid is added into the distilled
water and not vice versa. Stir and check
the specific gravity of electrolyte and add
sulphuric acid till the specific gravity be-
comes 1.240
Never add sulphuric acid to battery elec-
trolyte for topping up or increasing spe-
cific gravity. It would lead to sulphation.
Check the specific gravity with
hydrometer.
Stir with a glass rod.